General maintenance



Yüklə 5,16 Mb.
Pdf görüntüsü
səhifə6/14
tarix08.08.2018
ölçüsü5,16 Mb.
#61145
1   2   3   4   5   6   7   8   9   ...   14

12

Dwell - Is the amount of time the solenoid stays on to fire a ball. 

Setting the Dwell too high will decrease efficiency.  Setting the 

Dwell too low will cause inconsistent velocity.

•  The screen displays the current Dwell time(in milliseconds)

•  Press RIGHT or Press CENTER of D-Pad to change the    

  Dwell Time (Default is 15.0 ms)

•  Press UP or DOWN to increase/decrease the Dwell setting  

  (8.0-25.0 ms)

•  Press LEFT or Press CENTER of D-Pad to save setting and return  

  to CONFIG menu



Pull Debounce (PULL DEB) - Time in milliseconds the trigger 

pull must be held to register a valid trigger pull.  This eliminates 

electronic noise and vibrations that the board may wrongly interpret 

as a trigger action (trigger pull) and fire the marker.  Too low of a value will cause undesired 

trigger pulls.  Too high of a value will make it harder to achieve high rates of fire.

•  The screen displays the current Trigger Pull Debounce setting (in milliseconds)

•  Press RIGHT or Press CENTER of D-Pad to change the Trigger Pull Debounce setting    

  (default is 4ms)

•  Press UP or DOWN to increase/decrease the Pull Debounce setting (1-20 ms)

•  Press LEFT or Press CENTER of D-Pad to save setting and return to CONFIG menu



Release Debounce (REL DEB) - Time in milliseconds the trigger must remain released be-

fore next pull can be registered.  Too low of a value will cause undesired trigger 

pulls.  Too high of a value will make it harder to achieve high rates of fire.

•  The screen displays the current Trigger Release Debounce setting (in millisec 

 onds)

•  Press RIGHT or Press CENTER of D-Pad to change the Release Debounce  



  setting (default is 6ms) 

•  Press UP or DOWN to increase/decrease the Release Debounce setting (1-20  

 ms)

•  Press LEFT or Press CENTER of D-Pad to save setting and return to CONFIG  



 menu

AMB Level - Anti-Mechanical Bounce will help prevent “Run Away” 

during sustained firing which is described as the marker shooting 

extra shots when the user is not pulling the trigger.  A lower value 

will make it easier to maintain high rates of fire.  A higher value will 

prevent “Run Away.”  

•  The screen displays the current AMB Level (adjustable from level  

  0-10 with level 0 being  

 

off)



•  Press RIGHT or Press CENTER of D-Pad to change the AMB  

  Level (default is 0)

•  Press UP or DOWN to increase/decrease the AMB LEVEL setting  

 (1-10)


•  Press LEFT or Press CENTER of D-Pad to save setting and return  

  to CONFIG menu



Ball in Place (BIP) Time - Consecutive milliseconds the Eyes must sense a ball before they 

will allow the marker to fire. Increase this setting for slower feeding loaders to avoid chopping 

balls in the breech. Decrease this setting for use with faster feeding loaders to increase max 

ROF.  This setting only has an affect when the eyes are on and not malfunctioning.  If not us-

ing a force feed loader a setting of at least 10ms is recommended.

•  The screen displays the current BIP Time (in milliseconds)

•  Press RIGHT or Press CENTER of D-Pad to change the Ball In Place setting (default is 5ms)

  Press UP or DOWN to increase/decrease the BIP setting (1-20 ms)

•  Press LEFT or Press CENTER of D-Pad to save setting and return to CONFIG menu



Anti-Bolt Stick (ABS) Wait Time – The time in seconds that must expire after 

a shot before ABS is activated.  This helps prevent first shot drop-off.  ABS is a 

feature to compensate for stiction of the bolt which causes low velocity on first 

shots of a string.

•  The screen displays the current ABS Wait Time (in seconds)

•  Press RIGHT or Press CENTER of D-Pad to change the ABS Wait setting  

 

  (default is 60s)



•  Press UP or DOWN to increase/decrease the ABS Wait setting (10-200 sec, in  

  10 second increments)

•  Press LEFT or Press CENTER of D-Pad to save setting and return to CONFIG    

 menu



13

Anti-Bolt Stick (ABS) Dwell - Time that the dwell is increased by 

for the first shot when ABS is activated.  Too high of a setting may 

cause first shot of a string to have high velocity.  Too low of a set-

ting may cause excessive bolt stick or first shot drop off.

•  The screen displays the current ABS Dwell Time (in millisec 

 onds)


•  Press RIGHT or Press CENTER of D-Pad to change the ABS  

  DWELL setting (default is 3ms)

•  Press UP or DOWN to increase/decrease the ABS Dwell setting  

  (0-10 ms)

•  Press LEFT or Press CENTER of D-Pad to save setting and  

  return to CONFIG menu



Ramp Start - Number of Semi-Auto shots needed before selected 

firing mode kicks in (affects all firing modes but Semi-Auto and NPPL).

•  The screen displays the current Ramp Start setting (in # of shots)

•  Press RIGHT or Press CENTER of D-Pad to change the Ramp Start setting (default is 3    

 shots)

•  Press UP or DOWN to increase/decrease the Ramp Start setting (3-12 shots)



•  Press LEFT or Press CENTER of D-Pad to save setting and return to CONFIG menu

Ramp Sustain - Trigger Pulls per Second (TPS) that must be 

maintained to continue ramping (affects RAMP, PSPR and MILL 

modes).

•  The screen displays the current Ramp Sustain setting (in trigger  



  pulls per second)

•  Press RIGHT or Press CENTER of D-Pad to see current Ramp  

  Sustain setting (default is 3)

•  Press UP or DOWN to increase/decrease the Ramp Sustain set 

  ting (3-12 TPS)

•  Press LEFT or Press CENTER of D-Pad to save setting and  

  return to CONFIG menu

Ramp Reset - Time after the last trigger pull before Ramp Start 

Shot count will reset (affects all modes except Semi and NPPL).

•  The screen displays the current Ramp Reset (in seconds)

•  Press RIGHT or Press CENTER of D-Pad to change the Ramp Reset setting (default is 1.0)

•  Press UP or DOWN to increase/decrease the Ramp Reset  setting (0.1-1.0 sec)

•  Press LEFT or Press CENTER of D-Pad to save setting and return to CONFIG menu



Burst Shots - Determines how many shots are fired at each trigger 

pull when marker firing mode is BURST or PSP B.  This setting will 

only affect BURST and PSP B firing modes. 

•  The screen displays the current Burst Shots setting (in # of  

 shots)

•  Press RIGHT or Press CENTER of D-Pad to change the Burst  



  Shots setting (default is 3 shots) 

•  Press UP or DOWN to increase/decrease the Burst Shot setting  

  (2-6 shots)

•  Press LEFT or Press CENTER of D-Pad to save setting and return  

  to CONFIG menu

  Back – Return to MAIN Menu

•  Press RIGHT or Press CENTER of D-Pad when BACK is visible to  

  return to the MAIN Menu.



SYSTEM MENU

Settings under this menu affect secondary functions of the marker that do not have to do with 

firing characteristics. 

Navigating the System Menu 

•  Press the D-pad in the UP or DOWN directions to scroll through the SYSTEM    

 

  Menu options. The current setting for each option will be displayed on the  



  right side of screen.

•  To select a setting for modification press the D-Pad RIGHT or CENTER.  

•  Tilt the D-Pad UP or DOWN to modify the setting value.

•  Tilt the D-Pad LEFT or press CENTER to save the setting and go back to the  

  System Menu.  

Game Timer - Set the Game Timer countdown duration.

•  The screen displays the current Game Timer duration - MM = Minutes, SS =  

  Seconds (MM:SS)

•  Press the D-Pad Right or Center to change the duration time (default 7:10)

•  Press UP or DOWN to increase/decrease the 

  Game Timer minutes (00-99)




Yüklə 5,16 Mb.

Dostları ilə paylaş:
1   2   3   4   5   6   7   8   9   ...   14




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©www.genderi.org 2024
rəhbərliyinə müraciət

    Ana səhifə