10

  precision electronic pressure transducer.   

  This shows the marker pressure as    

  regulated by the ASA/Regulator.   

 

  The pressure transducer has a range of  



  50-250psi.  Out of this range,  

 

  pressure will not be displayed, and will  



  display LOW or OVER.

•  Shot Counter – The marker will keep    

  track of the number of shots fired.  This  

  number will increase each time  

 

  the solenoid is cycled and will be saved  



  even when power is disconnected.  Shot  

  Counter can be reset in the settings    

 menu.

•  AVG and Peak ROF’s Achieved - The Average ROF is the highest actual number of shots   



  that were started within 1 second.  The Peak ROF is the shortest time between 2 consecu 

  tive shots.  This can be reset by pressing the center on the joystick 2 times quickly  

 

  (Like double clicking a mouse).



•  Lube Gauge - The Lube Gauge will monitor how many shots have occurred since last time  

  the maker was lubricated.  This gauge must be reset by the user when the marker is lubed  

  for an accurate reading.  There is also an alert associated with the Lube Gauge (see page  

  15 for Lube Alert).

•  MAIN Menu – Press and hold CENTER on D-pad to enter the MAIN Menu (see below for    

  more details).



MAIN MENU

The display will show “MAIN MENU” at the top of the screen indicating the Main Menu.  

Press the D-pad to the RIGHT, LEFT, UP or DOWN directions to scroll through the MAIN 

Menu options.  Press CENTER on the D-pad to make a selection.

•  OFF – Turns Marker Off

•  CONFIG – Enters User CONFIGurations Menu (see below) 

•  SYSTEM – Enters SYSTEM Settings Menu (see below)

•  EXIT – Exits back to LIVE Mode

Note: MENU QUICK EXIT - As long as you 

are not currently modifying a setting, you 

can exit any menu at any time by pressing 

and releasing the trigger. This will take you 

back to LIVE Mode.

CONFIG MENU: 

Note:  Settings under this menu affect the markers firing characteristics and 

may not be modified when tournament lock is on.  Press the D-pad in the UP or 

DOWN directions to scroll through the USER CONFIGURATIONS Menu options.  

Press CENTER or RIGHT on the D-pad enter the selected option and see the 

current setting.



User Configurations

There are 3 fully customizable user configurations (or profiles).  The current user 

CONFIG NUM (Profile) is displayed on the screen (1, 2, or 3).

•  Only the settings under CONFIG menu are linked to a specific User Profile.

•  If Tournament Lock is active, the marker will beep when trying to make a  

 

  selection and you cannot modify any settings in the CONFIG tmenu.



•  Changing the values of a setting will only affect the Profile that is currently  

 

  chosen.  



  If the current Profile is 1, any changes to the user settings in the CONFIG menu will  

 

  only affect Profile 1.




11

FIRE MODE - Choose between the different firing modes

•  The current Firing Mode setting is displayed on the right side of the screen.

•  Press CENTER or RIGHT to change the Fire Mode setting

•  Press UP or DOWN to cycle through Firing Modes

•  Press CENTER or LEFT to save your selection

•  SEMI - Semi automatic firing shoots 1 shot per trigger pull up to the max ROF    

  (Rate of Fire) setting

•  RAMP – Semi auto shots (equal to Ramp Shot Start setting), then a Ramping    

  rate of fire up to the max ROF setting (if Ramp Sustain Trigger Pulls   

 

  per Second is achieved, see below)



•  BURST – Semi auto shots (equal to Ramp Shot Start setting), then multiple-   

  shot bursts at the max ROF.  The number of shots in the burst is adjustable in    

  the BURST SHOT setting.  If time between shots is longer than Ramp  

 

  Reset setting the marker goes back to Semi Automatic and the Ramp  



 

  Start shot counter is reset.

•  AUTO - Semi auto shots (equal to Ramp Shot Start setting), then Fully Automatic firing    

  at the ROF CAP setting.  If time between shots is longer than the Ramp Reset setting the  

  marker goes back to Semi Automatic and the Ramp Start shot counter is reset.

•  PSP B - Complies to 2010-2012 PSP rules using Burst mode as described above

•  PSP R - Complies to 2010-2012 PSP rules using Ramp mode as described above

•  MILL - Complies to 2010-2012 Millennium Series Rules using Ramp mode as described   

 above

•  NPPL – Complies with 2012 NPPL rules using Semi Auto mode as described above



ROF CAP - Choose between having the marker Rate of Fire Capped or Un-

capped.  Turning this setting ON will cap the marker at the ROF (•) ON setting.  

Turning this setting OFF will uncap the marker and allow the marker to fire as 

fast as paintballs can be loaded and detected by the eyes.

Note - Firing modes other than Semi may not be uncapped due to ASTM Safety 

Regulations.

•  The screen displays the current setting of whether ROF CAP is On or OFF

•  Press CENTER or RIGHT to change the ROF Cap setting

•  Press UP or DOWN to cycle through ON or OFF

•  Press LEFT or Press CENTER on D-Pad to save the setting and return to  

  CONFIG menu

ROF (•) ON- The maximum Rate of Fire with Eyes On (ROF Cap must be ON)

•  The screen displays the current ROF EYES ON setting 

•  Press RIGHT or Press CENTER on D-Pad to change the ROF with EYES ON    

 setting


•  Press UP or DOWN to increase/decrease the BPS setting  (8.0-25.0 BPS, in    

  0.1 BPS increments)

•  Press LEFT or Press CENTER on D-Pad to save setting and return to CONFIG    

 menu


ROF (•) OFF - The maximum Rate of Fire with Eyes OFF

•  The screen displays the current ROF EYES OFF setting 

•  Press RIGHT or Press CENTER on D-Pad to change the ROF with  

 

  EYES OFF setting



•  Press UP or DOWN to increase/decrease the BPS setting   

 

  (8.0-25.0 BPS, in 0.1 BPS increments)



•  Press LEFT or Press CENTER of D-Pad to save setting and return  

 

  to CONFIG menu



ROF Default - The maximum allowed Rate of Fire if the eyes be-

come dirty or malfunction.

•  The screen displays the current ROF Default setting (in BPS)

•  Press RIGHT or Press CENTER on D-Pad to change the ROF  

 

  Default setting (default is 8 BPS)



•  Press UP or DOWN to increase/decrease the BPS setting  (7-12  

  BPS, in 1 BPS increments)