9
requirements.
3
Commercial:
(a)
Integrated
Corporate
40%
1.5-1.75
(As per zoning
plan)
4 Level basement with the provision of parking and
services shall be allowed if it satisfies the public health,
fire and structural safety requirements.
(b)
Individual
SCOs
100%
3.0
Single basement not exceeding 3 metres shall be
permitted for storage, machine room of lifts, record,
godowns and strong rooms and only ancillary to the
permissible use of the site and for no other purposes.
(c) Booths
100%
1.0
Single basement not exceeding 3 metres shall be
permitted for storage.
4
Warehousing
60%
0.75
No basement shall be permitted
Note:
Basement shall be permitted free of FAR. Storage material in the basement shall be in accordance with the
provisions of National Building Code.
XVII. Building lines in front and rear of buildings
These shall be provided in accordance with rules 51, 52 and 53 of the Punjab Scheduled Roads and
Controlled Areas Restriction of Unregulated Development Rules, 1965.
XVIII. Architectural control
Every building shall conform to architectural control prepared under rule 50 of the Punjab Scheduled Roads
and Controlled Areas Restriction of Unregulated Development Rules, 1965.
XIX Relaxation of agricultural zone.-
In the case of any land lying in Agriculture zone, Government may relax the provisions of this development
plan-
(a)
For use and development of the land into a residential or industrial colony provided the coloniser has
purchased the land for the said use and developed prior to the material date and the coloniser secures
permission for this purpose as per Rules.
Explanation:
The word 'purchase' in the regulation shall mean acquisition of full proprietary rights and
no lesser title, such as agreement to purchase etc.
(b)
The site should not fall within restricted belt notified under „the Works of Defence Act, 1903‟ around
Defence installations, if any.
XX. Density: -
Every residential sector shall be developed to the sector density indicated as prescribed for it in the drawing
subject to a maximum of 20 percent variation allowed on either side of the prescribed sector density.
XXI. Provisions of Information Technology Units and Cyber Parks/Cyber Cities
(i)
Location
(a)
Information Technology Industrial Units will be located in Industrial Areas/Industrial
Zones only;
(b)
Cyber Parks/ Information Technology Parks will be located either in Industrial Areas or
Industrial Zones abutting on sector roads in the form of integrated development.
However, no manufacturing units will be permitted in such parks;
(c)
Cyber Cities:- The location of such a facility will be decided by the Government;
(ii)
Size
Serial
Number
Type
Size
1
Information Technology Industrial Unit
1 to 5 acres
2
Cyber Park / Information Technology Park
5 to 15 acres