To treat structural voids above sites of termite activity in masonry, consult section(s) of this label appropriate to the element of 

construction, FOAM APPLICATIONS or CONTROL OF WOOD INFESTING PEST for detailed directions on any of these treatment 

procedures. Treatment of voids in block or rubble foundation walls must be closely examined. Applicators must inspect areas of 

possible runoff as a precaution against application leakage in the treated areas. Some areas may not be treatable or may require 

mechanical alteration prior to treatment. All leaks resulting in the deposition of termiticide in locations other than those prescribed on 

this label must be cleaned up prior to leaving the application site (refer to Use Instructions). 

 

RESTRICTION: Do not allow people or pets to contact or to reoccupy the contaminated areas of the structure until the clean-up is 

completed. 

 

3. BATH TRAPS: If termite activity is observed within 2 feet of the bath trap, then exposed soil or soil covered with tar or similar type of 

sealant around plumbing and/or drain pipe entry areas must be treated. Tar or sealant may have to be removed to allow for adequate 

soil treatment. An access door or inspection portal should be installed if one is not present. After inspection and removal of any wood or 

cellulose debris, the soil can be treated by rodding or drenching the soil at the volume of no less than 3 gallons of solution per square 

foot. 

 

4. SHOWER OR FLOOR DRAINS: If termite activity is observed within 2 feet of a shower of floor drain in the slab, the soil beneath the 



drain must be treated. Drill through the slab adjacent to the drain and use sub-slab injection to apply solution to the soil. Multiple access 

points may be drilled adjacent to the drain. Treat soil at a volume of 1 gallon of solution per square foot. 

 

FOAM APPLICATIONS 

Construction practices, soil subsidence and other factors may create situations in which a continuous chemical treated zone cannot be 

achieved using conventional treatment alone. In situations where necessary, conventional application methods can be supplemented 

through use of foam generating equipment, or similar devices, to provide a continuous treated zone. 

 

Foam application may be made alone or in combination with conventional application methods, provided that the labeled amount of 



active ingredient per unit area is used. 

 

Foam Application Use Directions: Mix appropriate concentration of DOMINION 2L in water and add the manufacturer's 

recommended quantity of foam agent to the DOMINION 2L solution (see table for foaming recommendations). Apply a sufficient 

volume of DOMINION 2L foam alone or in combination with liquid solution to provide a continuous treated zone at the labeled rate for 

specific application sites. 

 

NOTE:  Add the manufacturer’s recommended quantity of foam agent to the DOMINION 2L solution. 



 

[Only one of the tables below will be used based upon the size of container offered for sale] 

[FOR 240 ML SIZE ONLY] 

MIXING TABLE - DOMINION 2L FOAM 

IMI 2 lb. (mL) 

GALLONS OF WATER 

FOAM EXPANSION 

RATIO 

FINISHED FOAM  

(0.05% ai) 

160 


20:1 


20 gal 

80 


10:1 


10 gal 

40 


5:1 


5 gal 

 

[FOR 55 FL OZ SIZE ONLY] 

MIXING TABLE - DOMINION 2L FOAM 

IMI 2 lb (fl oz) 

GALLONS OF WATER 

FOAM EXPANSION 

RATIO 

FINISHED FOAM  

(0.05% ai) 

6.9 


25:1 


25 gal 

2.5 


10:1 

5:1 



13.8 

50:1 



50 gal 

2.5 


20:1 

10:1 



 

Depending on the circumstances, foam applications may be used alone or in combination with liquid solution applications. Applications 

may be made behind veneers, piers, chimney bases, into rubble foundations, into block voids or structural voids, wall voids, under 

slabs, stoops, porches, or to the soil in crawlspaces, and other similar voids. 




  

 

11 



 

Foam and liquid applications must be consistent with volume and active ingredient instructions in order to ensure proper application 

has been made. The volume and amount of active ingredient are essential to an effective treatment. At least 75% of the gallons of 

DOMINION 2L must be applied as a typical liquid treatment. The remaining 25% or fewer gallons is delivered to appropriate locations 

using a foam application. 

 

NOTE: When foam is used solely to kill subterranean termites in above ground locations (such as feeding galleries in wooden framing, 



or in voids with framed walls), and whenever the target pest is other than subterranean termites (drywood termites, beetles, ants, etc.) 

dilute solutions of DOMINION 2L may be expanded by foaming without concentrating the DOMINION 2L  solution as previously 

described for soil applications. Add the manufacturers' recommended volume of foaming agent to produce foam of the desired 

expansion ratio. Use application tips and methods suitable to the site and pest. 



 

CONTROL OF WOOD INFESTING PESTS 

 

For control of above ground termites and carpenter ants in localized areas, apply a 0.05 to 0.1% solution of sufficient  volume of 

DOMINION 2L  foam to voids and galleries in damaged wood, and in spaces between wooden structural members and between the sill 

plate and foundation where wood is vulnerable. Applications may be made to inaccessible areas by drilling, and then injecting the 

suspension or foam with a suitable directional injector into the damaged wood or wall voids. Termite carton nests in building voids may 

be injected with a 0.05 to 0.1% suspension or foam. Multiple injection points to varying depths may be necessary. It is desirable to 

physically remove carton nest material from building voids when such nests are found. Application to attics, crawl spaces, unfinished 

basements, or man-made voids may be made with a coarse fan spray of 0.05 to 0.1% solution or foam to control exposed worker and 

winged reproductive forms of termites or carpenter ants. This type of application is intended to be a supplemental treatment for control 

of above ground subterranean termites and carpenter ants. 

 

It is recommended to remove or prune away any shrubbery, bushes, and tree branches touching the structure. Vegetation touching the 



structure may offer a route of entry for ants into the structure. This may allow ants to inhabit the structure without coming in contact with 

the treatment. If nests are found, direct treatment of DOMINION 2L can be made to theses nests. 

 

Use a 0.05% to 0.1% solution to control existing infestations  or to prevent infestation by termites or carpenter ants in trees, utility 



poles, fencing and decking materials, landscape timbers and similar non-structural wood-to-soil contacts. If possible, locate the interior 

infested cavity and inject a 0.05 to 0.1% solution or sufficient volume of DOMINION 2L foam using an appropriate treatment tool with a 

splash back guard. These non-structural wood-to-soil contacts may also be treated by applying a solution to the soil as a spot 

application or continuous treated zone applied as a drench or by rodding around the base of the point(s) of soil contact(s). Rod holes 

should be placed approximately 3 inches away from the soil contact point(s) and spaced no more than 12 inches along the perimeter of 

the soil contact(s). For small poles or posts (< 6 inches in diameter), apply 1 gallon per foot of depth. For larger constructions, apply 4 

gallons per 10 linear feet per foot of depth. Retreat as needed to maintain protection. 

 

Termite carton nests in trees may be injected with a 0.05 to 0.1% solution or sufficient volume of foam using a pointed injection fool. 



Multiple injection points to varying depths may be necessary. Removal of carton material from trees is desirable but may not be 

necessary when foam application is used. In some instances, a perimeter application of a 0.05% to 0.1% solution applied to soil around 

the root flare of the tree may be necessary to prevent reinfestation by termites in the soil. For small trees (' 6 inches in diameter), apply 

1 gallon of solution. For larger trees, apply 4 gallons per 10 linear feet (measured as the circumference at the root flare). 

 

For protection of firewood or other wood products stored in contact with soil from carpenter ants and termites, treat soil prior to stacking 



with a 0.05 to 0.1% solution at 1 gallon per 10 square feet to prevent infestation. Curative application to the soil around firewood or 

other wood products stored in contact with soil may be made as described for non-structural wood-to-soil contacts (above). 

 

Drywood termites and wood-infesting beetles or borers (such as, but not limited to, powder post beetles, anobiid or deathwatch 

beetles, false powder post beetles, old house borers, wharf borers, or ambrosia or bark beetles). Galleries and structure voids can 

be treated with sprays, mists, or foams of a 0.05% to 0.1% DOMINION 2L solution. Locate galleries by using visual signs (frass or 

pellets, blistered wood, emergence or clean out holes), the presence of live insects, mechanical sounding techniques, or listening 

devices (e.g., stethoscopes, acoustic emission detectors). Penetrate the gallery system by drilling holes to receive the injector tip or 

treatment tool. Distribute drill holes to adequately cover the gallery system. [NOTE: Avoid drilling where electrical wiring, plumbing 

lines, etc. are located.] Apply DOMINION 2L  solutions as a low pressure (about 20 psi) spray or by misting or, where appropriate, by 

foaming. It is not necessary to treat to the point where runoff is detected from adjacent holes. ]NOTE: Do not apply where electrical 

shock hazards exist.] Drill holes should be sealed after treatment. Also, wood surfaces can be sprayed or misted with a 0.05% to 

0.1% solution or, where appropriate, use a sufficient volume of foam. For inaccessible surfaces, drill and treat the interior of structural 

voids. Surfaces treated may include exposed wooden surfaces in crawlspaces, basements, or attics, wooden exterior surfaces such as 

decks, fencing, or siding, structural voids, channels in damaged wood, in spaces between wooden members of a structure, and 

junctions between wood and foundations. Apply by brushing or as a coarse, low pressure (about 20 psi) spray to the wood surface; 

apply sufficient volume to cover the surface to the point of wetness, but avoid applying to the point of runoff. When spraying overhead 

in living areas, cover surfaces below the treated area with plastic sheeting or similar material, Avoid contact with treated surfaces until 

spray deposits have dried. Retreat as needed to maintain protection. 



 