Menu 9: Manual Mode


In this Submenu you can see which output is on (█) and which is off (.); In this case the automatic is still active

You can also see what the outputs are used




Output 1:

1= L1: Load 1 Output (Power-Mosfet-Transistor)

2-7= R2-R7: Relay 2 – Relay 7 (12V/24V/110V/220V)

8=Be Beeper on/off

If you press now key 1 till 8 in this Sub-Menu then you can switch all Output manually. In this case the automatic is switched off and manual mode is active. That means that no output is switched on automatically any more.

Output Group 2:

1=PW=Solar

2=Ni=NiCd

3=L2=Load 2

4=L3=Load 3

5=L4=Load4

6=L5=Load 5

7=L6=Load 6

8=L7=Load 7
(not all Units have Load 3-5; Load 6+7 for future extension)
Analogue 1:

1:Sensor_batt = Battery voltage

2:U_ausg = Output voltage

3:Sensor_1 = Moving-Detector

4:Sensor_2 = Generator is running feedback

5:Sensor_3 = Temperature Solarpanels

6:Sensor_temp=Temperature-Kompensation Ambient Temperature

7:Reserve

8:Wahlschalter=Program-Selector
Analogue 2:

9=Analog_9 = Battery-Bank 2

10=Analog_10 = Battery-Bank 2

11=Analog_11 = Current external Load

12= I_Load 2 = Current Load Block 2

13=I_Load 1 = Current Load Block 1

14=I_Solar = Current Solar

15=U_NiCd = NiCd Voltage


Inputs:

1:Input_0 = Base Position Rotate

2:Input 1 = Start Motor Manual / Final Position Rotate horizontal

3:Input_2 = Stop Motor Manual / Base Position Rotation vertical

4:Input_3 = Stop Motor Manual / Final Position Rotation vertical

5:Input_4 = Theft-Alarm 1

6:Input_5 = Theft-Alarm 2

7:Input_6 = Theft-Alarm 3

8:Input_7 = Theft-Alarm 4
Overview Functions by the PC-Software MP_Remote


  • Select the according serial COM-Port. If you use a USB-Adapter the according COM-Port has to be selected.

  • Select the according Software and you have access to all documents and Plans by the Menu „Software and „Doku“.

  • Monitoring and fully control of the Metamorphosis (changing of all Parameter etc). This can be realized also by modem and Mobile-Phone. You can press the keys with the mouse or with the key Alt + Number.

  • Loading of the stored Measurement-Values in a Text-File pressing the key „Load Data to PC”

  • Open this file with Measurement-values by the Menu “Data, View Uploaded Data”

  • Loading of a new Program; Start the „Bootloader“-Software from the Menu. In there you have to select the serial COM-Port and the according Program.

  • If you have a Modem connected then you can dial with „Telephone“ the according number. In this Menu you can also disconnect the connection.

  • The connection can be established by Mobile phone as well.

  • Activation of the Sending of Data to Logview or any other Program by the Menu Data, „Data, Send Data for Logging (LogView)“. After activation Stop the MP_Remote and Start Logview. And select as Device “Metamorphose_Solar_e”. Refer to Document “Logview-Info” for more Information.

  • All Parameters which are Setup in Menu 8 can be uploaded to a Text-File by the Menu “Data, Get Parameters”.

  • They can be modified in the Text-File. Select the File by Menu Data, change Parameters. Then they can be loaded again to the Metamorphosis by Menu “Data, Send Parameter”. By that you have more Information on each Parameter and a backup of your Data is possible.

  • All Parameters which are Setup in the Universal-Module can be uploaded to a Text-File by the Menu “Data, Get Data Universal-Module”.

  • They can be modified in the Text-File. Select the File by Menu Data, change Parameters. Then they can be loaded again to the Metamorphosis by Menu “Data, Send Data Universal-Module”. By that you have more Information on each Parameter and a backup of your Data is also possible.

  • By the Button „Display all Data“ you can enlarge the Display and more Data are shown. But for the Input of Data it is better to press the Button “Stop Display for Input of Data” temporarily.

  • By the key “Simulation” a Simulation-Value for testing can be Setup

  • In Menu “Data, Edit Input/Output-List” the Name of all Inputs and Outputs can be Setup for Documentation.

Installation of the PC-Software MP_Remote


This Software is for Loading of the measured values on the PC and fully Operating the Metamorphosis with the PC

Installation

On the CD you find the Software „MP_Remote“. How to install?




  • For this call Setup_MP_Remote_eng.bat on the CD.

If you have Vista register the OCX in this way:
Call Programs, Accessoires, command prompt; Then right click „run as Administrator“; and „continue“; Then navigate to the folder c:\Metamor by
C:
Cd Metamor
Then enter “register“ and „exit“

  • Now connect the metamorphosis with the cable you get to the serial interface of the PC

  • Then call the program C:\Metamor\MP_Remote.exe

  • After the start selected the COM-Port. Begin with COM1 and if it doesn't go select COM2


Loading of the Logged Data to the PC

  • Now press the button ”Upload”; the data will now be loaded and ”End” will be displayed when finished.

  • Now you can look at the data with the function ”Data” and "View uploaded data" you can write comments, print it and import them in Microsoft Word or Excel for example (import to Excel: File, open, Typ "all files", then go to folder C:\Meta\data.txt, then Data is separated by Blank)




Yüklə 0,88 Mb.

Dostları ilə paylaş:
1   ...   6   7   8   9   10   11   12   13   14




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©www.genderi.org 2024
rəhbərliyinə müraciət

    Ana səhifə