A systematic Characterization of Application Sensitivity to Network Performance



Yüklə 0,74 Mb.
Pdf görüntüsü
səhifə51/51
tarix15.10.2018
ölçüsü0,74 Mb.
#74178
1   ...   43   44   45   46   47   48   49   50   51

137
0
FT
IS
MG
1
s
5.8
173.2
18.7
17.8
8.3
-
21.3
18.2
10.8
-
21.5
16.8
15.8
-
20.1
16.8
30.8
-
19.6
18.3
55.8
170.6
21.3
22.6
80.8
159.1
21.1
21.3
105.8
171.6
21.4
23.5
Table B.7: NPB Run Times varying gap
This table shows the run time, in seconds, of the NPB while varying gap. A switch bug caused FT
to crash often. Unfortunately, the fixed switches were not available in time for this thesis, and the
work-around would significantly perturb the results.
2
FT
IS
MG
1
s
5
173.2
18.7
17.8
7.5
178.4
22.6
18.2
10
-
20.6
19.2
15
-
21.1
17.8
30
-
21
55
-
19.8
22.1
80
-
19.8
21.9
105
-
19.8
22.2
Table B.8: NPB Run Times varying latency
This table shows the run time, in seconds, of the NPB while varying latency. A switch bug caused FT
to crash for high latency. Unfortunately, the fixed switches were not available in time for this thesis,
and the work-around would significantly perturb the results.
Bandwidth
FT
IS
MG
MB/s
1.19
661
-
60.9
4.6
225.7
22.6
25.5
11.2
186.2
23
20
15
171.8
22.1
19.6
19
177.1
22.1
23.5
37.5
173.2
18.7
17.8
Table B.9: NPB Run Times varying Bandwidth
This table shows the run time, in seconds, of the NPB while varying Gap. Bandwidth is used so as
to make an easier comparison to known systems.


138
Ops/sec
Latency (
3
s)
Measured
10
50
100
500
1000
2000
4000
198
7.3
7.2
7.3
8.2
9.4
11.9
16.4
199
-
-
-
-
-
11.3
-
396
-
9.9
-
-
-
-
-
397
10.1
-
10
11
12.3
14.9
-
398
-
-
-
-
-
-
20.5
602
13.8
13.4
14
14.8
-
-
26.5
603
-
-
-
-
16.7
18.8
-
762
-
-
-
-
-
-
35.1
773
-
-
-
-
-
-
34.7
774
-
-
-
-
-
-
33.7
790
-
-
-
-
-
-
33.9
799
-
16.1
15.9
16.9
-
22
-
800
15.6
-
-
-
-
-
-
801
-
-
-
-
18.8
-
-
943
-
-
-
-
-
28.8
-
949
-
-
-
-
-
25.6
-
950
17.6
-
-
18.8
21.8
-
-
951
-
-
18.3
-
-
-
-
952
-
17.3
-
-
-
-
-
958
-
-
-
-
-
27.7
-
1000
-
-
-
-
24.9
-
-
1006
18.9
-
21.1
20.1
-
-
-
1007
-
19
-
-
-
-
-
1009
-
-
-
-
25.8
-
-
1045
-
-
23.8
-
-
-
-
1053
19.9
-
-
-
-
-
-
1054
-
20
-
-
-
-
-
1055
-
-
-
21.5
-
-
-
Table B.10: SPECsfs Response Times in varying Latency on the SCSI system
The table shows the average response time, in milliseconds, for the SCSI system running NFS version
2 over UDP using the SFS 2.0 operation mix while varying latency.


139
Ops/sec
Latency (
4
s)
Measured
10
15
50
100
150
1000
4000
298
3.4
3.5
3.8
3.7
3.9
5.9
13.4
397
4
3.9
-
4
4.1
-
-
398
-
-
4
-
-
6.3
16.4
494
4.5
4.5
-
4.6
4.9
7
-
495
-
-
4.6
-
-
-
20.5
595
4.9
5.2
4.9
5
5.2
7.6
17.4
696
6.1
5.8
6
6.2
6.2
8.7
20.1
791
-
-
-
-
-
-
24.5
797
7.2
7.2
7.3
7.6
7.9
-
-
798
-
-
-
-
-
10.6
-
900
-
-
9
-
-
-
-
901
8.8
-
-
-
-
-
-
902
-
9
-
9.5
9.4
-
25.8
903
-
-
-
-
-
12.8
-
1001
11.4
-
-
-
-
-
-
1002
-
-
-
11.9
11.1
-
-
1003
-
11.5
10.8
-
-
-
-
1004
-
-
-
-
-
13.7
-
1006
-
-
-
-
-
-
31.8
1069
-
-
-
-
-
-
46.3
1121
-
-
-
-
-
-
44.2
1170
-
-
-
-
-
-
42.3
1188
-
-
-
-
-
-
41.3
1204
-
14.8
14.6
14.6
-
-
-
1205
15
-
-
-
-
-
-
1207
-
-
-
-
-
17.1
-
1304
18.7
-
-
-
-
-
-
1305
-
18.2
-
-
-
-
-
1306
-
-
18.1
18.5
-
-
-
1307
-
-
-
-
-
22.3
-
1400
-
21.6
22.1
21.1
-
-
-
1402
-
-
-
-
-
25.7
-
1405
21
-
-
-
-
-
-
1499
-
31.2
-
-
-
-
-
1501
-
-
-
-
-
30.1
-
1503
30.8
-
-
-
-
-
-
1505
-
-
-
31
-
-
-
Table B.11: SPECsfs Response Times varying Latency on the RAID system
The table shows the average response time, in milliseconds, for the RAID running NFS version 2
over UDP using the SFS 2.0 operation mix while varying latency.


140
Ops/sec
Overhead (
5
s)
Measured
80
85
90
95
100
105
130
180
280
298
3.4
-
-
3.9
3.6
3.8
4.1
5.1
6.6
299
-
3.8
-
-
-
-
-
-
-
397
4
-
-
4
4.2
-
-
-
-
398
-
4
-
-
-
4.3
4.8
5.6
7.8
494
4.5
4.5
-
4.7
4.6
4.7
5.3
6.6
10.1
595
4.9
5
-
5.3
5.4
5.3
6.3
-
14.9
596
-
-
-
-
-
-
-
7.7
-
615
-
-
-
-
-
-
-
-
90.3
627
-
-
-
-
-
-
-
-
89.8
638
-
-
-
-
-
-
-
-
89.5
651
-
-
-
-
-
-
-
-
88.3
660
-
-
-
-
-
-
-
-
87.5
679
-
-
-
-
-
-
-
-
86.7
692
-
-
-
-
-
-
-
-
86.2
696
6.1
6
-
6
6.3
-
7.1
9.2
-
697
-
-
-
-
-
6.4
-
-
-
704
-
-
-
-
-
-
-
-
52.9
797
7.2
7.4
-
7.9
7.6
8
9
12.1
-
901
8.8
8.5
-
9.4
-
9.8
-
-
-
902
-
-
-
-
9
-
-
-
-
903
-
-
-
-
-
-
10.3
17.3
-
987
-
-
-
-
-
-
-
55.7
-
1001
11.4
-
-
-
-
12.8
-
-
-
1002
-
-
-
11.9
11.6
-
14.1
-
-
1003
-
11.5
-
-
-
-
-
-
-
1127
-
-
-
-
-
-
48.9
-
-
1168
-
-
-
-
-
-
47.9
-
-
1204
-
15.7
-
-
-
-
-
-
-
1205
15
-
-
16.2
-
-
-
-
-
1206
-
-
-
-
-
19
-
-
-
1207
-
-
-
-
17.6
-
24.6
-
-
1217
-
-
-
-
-
-
46.5
-
-
1282
-
-
-
-
-
41.8
-
-
-
1304
18.7
-
-
-
-
21.9
-
-
-
1307
-
-
-
22.7
-
-
-
-
-
1309
-
20.4
-
-
23.2
-
-
-
-
1330
-
-
-
-
40.6
-
-
-
-
1331
-
-
-
-
-
40.4
-
-
-
1338
-
-
-
31.4
-
-
-
-
-
1359
-
-
-
39
-
-
-
-
-
1378
-
-
-
-
39
-
-
-
-
1404
-
21.8
-
-
-
-
-
-
-
1405
21
-
-
-
-
-
-
-
-
1456
-
35.3
-
-
-
-
-
-
-
1503
30.8
-
-
-
-
-
-
-
-
Table B.12: SPECsfs Response Times varying Overhead on the RAID
The table shows the average response time, in milliseconds, for the RAID running NFS version 2
over UDP using the SFS 2.0 operation mix while varying overhead.


141
Ops/sec
Overhead (
6
s)
Measured
80
105
130
180
280
480
580
198
7.3
7.1
7.4
7.6
8.5
9.7
10.5
396
-
-
-
10.8
-
-
-
397
10.1
10.1
10.2
-
11.7
-
-
398
-
-
-
-
-
14.6
16.6
538
-
-
-
-
-
-
54.6
602
13.8
13.8
14
-
-
-
-
603
-
-
-
14.7
16.7
-
-
604
-
-
-
-
-
32.1
-
798
-
-
16.9
18.1
-
-
-
799
-
16.2
-
-
25.8
-
-
800
15.6
-
-
-
-
-
-
801
-
-
-
-
35.9
-
-
950
17.6
18.7
-
-
-
-
-
951
-
-
-
23.2
-
-
-
952
-
-
19.5
-
-
-
-
1005
-
21.8
21.5
-
-
-
-
1006
18.9
-
-
-
-
-
-
1029
-
24.9
-
-
-
-
-
1042
-
-
24.8
-
-
-
-
1053
19.9
-
-
-
-
-
-
Table B.13: SPECsfs Response Times varying Overhead on the SCSI system
The table shows the average response time, in milliseconds, for the SCSI system running NFS version
2 over UDP using the SFS 2.0 operation mix while varying overhead.


142
Ops/sec
Bandwidth(MB/s)
Measured
26
14.5
11.3
10.6
9.1
5.9
4.5
2.5
1.2
198
7.1
7.2
7.3
7.3
7.2
7.5
7.5
7.9
10.6
396
9.8
10
10
-
-
10.2
-
11.3
-
397
-
-
-
-
10.1
-
10.4
-
15.7
602
-
13.5
-
-
13.6
-
-
-
-
603
-
-
14
-
-
13.9
14.3
15.7
-
604
-
-
-
-
-
-
-
-
25.3
758
-
-
-
-
-
-
-
-
35.8
759
-
-
-
-
-
-
-
-
35.9
762
-
-
-
-
-
-
-
-
35.7
774
-
-
-
-
-
-
-
-
34.4
797
-
-
15.9
-
15.7
15.8
16.5
-
-
798
15.5
15.8
-
-
-
-
-
-
-
799
-
-
-
-
-
-
-
18.4
-
905
17
-
-
-
-
-
-
-
-
949
-
-
17.4
-
-
18.4
-
20.9
-
950
-
-
-
-
18.4
-
18.7
-
-
951
-
17.5
-
-
-
-
-
-
-
952
17.4
-
-
-
-
-
-
-
-
1004
-
-
-
-
-
20.1
-
-
-
1005
-
-
19.1
-
19.4
-
19.8
-
-
1006
-
19
-
-
-
-
-
-
-
1007
18.9
-
-
-
-
-
-
22.1
-
1014
27.7
-
-
-
-
-
-
-
-
1039
26.9
-
-
-
-
-
-
-
-
1052
-
-
-
-
-
-
21.4
-
-
1053
-
-
-
-
20.3
-
-
23.6
-
1054
20.3
-
20.5
-
-
-
-
-
-
1055
-
20
-
-
-
21.2
-
-
-
1074
26.1
-
-
-
-
-
-
-
-
1089
24.9
-
-
-
-
-
-
-
-
1097
22.7
-
-
-
-
-
-
-
-
Table B.14: SPECsfs Response Times varying Bandwidth on the SCSI system
The table shows the average response time, in milliseconds, for the SCSI system running NFS version
2 over UDP using the SFS 2.0 operation mix while varying bandwidth.

Yüklə 0,74 Mb.

Dostları ilə paylaş:
1   ...   43   44   45   46   47   48   49   50   51




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©www.genderi.org 2024
rəhbərliyinə müraciət

    Ana səhifə